See how simple it is to take measurements with the HMP PDGpro:

Prepare the measurement by setting up the hydraulics and mechanics. Switch on the measuring device.

The menu navigation of the HMP LFGpro will guide you reliably through the measuring process.

Welcome. The start display shows the charging status of logging unit + printer and also the GPS activity.

With the arrow keys, please select the corresponding function and confirm it by pressing the [Enter] key.

Basically - active functions are colored, inactive are grey.

Symbol Statisches Plattendruckgerät = Messung startenMeasuringSymbol SpeicherMemorySymbol EinstellungenSettings

A security query appears asking whether dial gauge and measuring head are connected correctly. Confirm with ENTER.

If the GPS is switched on, the measuring point is localised. Confirm with ENTER when the coordinates appear. If you confirm before, the measurement is started without GPS.

HMP PDG videoHMP PDG video

HMP PDGpro - display - reset dial gauge

Set the load to zero by confirming the selection.

Now increase the load to 0.01MN / m². For this, pump the hydraulic pump until the value is reached.

Set the dial gauge to zero by confirming with "Enter". The first measuring point, the preload, will be stored.

Now follows the gradual loading and unloading of the load plate.

HMP PDGpro - display - hold measurement 02

The set values ​​of the measuring points for the static plate load test according to DIN 18134 are stored in the measuring instrument and are displayed in the upper line.

Slowly increase the loading until the next set value and hold it for about 1 minute by pushing the pump.

As soon as the settlement value remains stable, accept the measured values ​​with "Enter".

HMP PDGpro - display - save measurement 02

By confirming with "Enter" again, the values are finally stored and the next set value will be displayed.

If necessary, you can also discard this value, in order to get closer to the set value of the load stage by loading or unloading.

By confirming with "Enter" again, the values are finally stored and the next set value will be displayed.

HMP PDGpro - display - hold measurement 04

Now again increase the loading gradually until the next set value is reached.

Hold and store the relevant values.

Increase the loading gradually until the next set value and continue as described above.

HMP PDGpro - display - hold unload measurement 08

If the indicated set value gets lower, the unloading starts.

Reduce the loading by carefully turning the valve of the hydraulic until the set value is reached. Hold this value for about 1 minute and store it.

Decrease the loading gradually until the next set value is reached. Hold and store the relevant values.

After the gradual unloading, the second load starts.

HMP PDGpro - Start second load

Now again increase the loading gradually until the next set value is reached.

Hold and store the relevant values.

After storing the last load stage, the result is shown in the display.

Measured data

HMP PDGpro - display measured data - memory

Here you can find all stored measurements clearly arranged for further processing and documentation.

HMP PDGpro - display measured data - memory - scroll and select a measurement serie

Individual settings

HMP PDGpro -  individual settings of the static plate load tester

Adjust the display and device configurations to your requirements. Regarding menu navigation just choose one of the various languages and use nationally usual measuring units.

HMP PDGpro - display settings for example settings of device and display

Note

The procedure of the Static Plate Load Test is standardized in DIN 18134 and ASTM D1195/1196. Comprehensive correlations to direct test methods are available.